Herunterladen Inhalt Inhalt Diese Seite drucken

Windhager BioWIN 2 Touch Montageanleitung Seite 16

Mit wochenbehälter
Vorschau ausblenden Andere Handbücher für BioWIN 2 Touch:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
2.
Installation sequence
2.2 Removing the crate
– Remove both fastening straps – Fig. 4.
– Remove wooden crate. Caution: The cladding door is loose inside the crate!
– Remove the side panel from the hopper by unscrewing both cross screws at the top (Fig. 5) and then lifting off the
side panel – Fig. 6.
– Remove the pedestal by taking out 3 screws each on both sides (Fig. 7) and then lifting off the pedestal – Fig. 8.
CAUTION
– Lift the container off the pallet and rotate it by 180° – Fig. 9.
Fig. 4
Remove the fastening straps
Fig. 6
Remove side panel
Fig. 8
Remove pedestal
The pedestal must be dismantled! Otherwise, it is not possible to install the tank cor-
rectly on the boiler; leaks or inleaked air would result.
Fig. 5
Remove 1 Phillips screw in each case
Fig. 7
Remove 6 screws
Fig. 9
Rotate hopper in correct position
16
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading