Before each fault clearance
− switch off device
− wait until the drum is stationary
− pull out main plug
After each fault clearance, put into operation and recheck all security installations.
Fault
Device doesn't start
The device operates with
interruptions
Unusual sounds
Unusual vibrations
Unsatisfactory verticulating
result
Type
Model
Motorrating P
1
Mains voltage / Mains frequency
Mains fuse
No-load speed n
0
Working width

Possible faults

Possible cause
no power
Extension cable defect
Main plug, motor or switch defect
Protective motor switch has tripped
Extension cable defect
Internal fault.
ON/OFF button defective.
Drum is blocked
Toothed belt slips
Loose screws, nuts or other fasteners
Cutting blade damaged or dull
Work depths too deep
Lawn too high
Work depth too low
Dull blades
Discharge opening blocked
Lawn too high

Technical data

Remedy
Check power supply, power socket and fuse
protection
Check extension cable, exchange defect cable
immediately
Have main plug, motor or switch checked by an
approved electrician or replaced by original
spare parts
1. Work depth too deep
2. Drum blocked
remove the blockage
3. Grass too long
mow the grass
Allow the motor to cool down approx. 15
minutes before continuing to work
Check extension cable, exchange defect cable
immediately
Please contact the after sales service.
Please contact the after sales service.
Remove the blockage
Please contact the after sales service.
Tighten all parts; contact customer service if the
noises continue to occur.
Please contact the after sales service.
Set a lower work depth
Mow the lawn before thatching
Set a greater work depth
Please contact the after sales service.
Empty the grass catching bag and remove the
blockage
Mow the lawn before thatching
VT 36
VT 40
1600 W
S6 – 40%
230 V~ / 50 Hz
10 A inert
2800 min
–1
362 mm
reduce work depth
VT 36
VT 40
2000 W
S6 – 40%
393 mm
17