Herunterladen Inhalt Inhalt Diese Seite drucken

Temperature Alarm; Power Failure; Defrosting - Gram K 200 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
Temperature regulation:
+ -
Push this key once more, or keep it pressed for more than 1 second; the
temperature value will change in steps of 1°C. When the display shows the
desired temperature value, let go of the key, and the setting has been made.
During setting of the temperature value, the digits in the display flash.
The controller will automatically return to normal displaying, if the key has not
been used for more than 5 seconds.

Temperature alarm

The controller is equipped with a temperature alarm, that monitors the cabinet temperature.
If the cabinet temperature exceeds the alarm value for more than 90 minutes, the display
starts flashing, and simultaneously the highest temperature during the alarm period is
displayed. The alarm is stopped by pushing
cabinet temperature.
Alarm temperature:
Refrigerator: 4°C above the setpoint
Freezer: 6°C above the setpoint

Power failure

In case of disconnected power supply, the controller will always return to the user set
temperature.
Startup with temperature above alarm temperature: The compressor starts immediately. The
display shows the alarm temperature until
temperature is displayed.
Startup with temperature below alarm temperature: The compressor starts after 10 minutes.
The display shows the actual temperature until the setpoint is reached.

Defrosting

K/KG 200/400:
Defrosting occurs during compressor standstill periods. The controller has an automatic
defrosting function. The compressor will be stopped for 20 minutes at every 4 hours of
compressor running time. After the 20 minutes has elapsed, the controller measures the
cabinet temperature every 2 seconds, and if the temperature exceeds 6°C the compressor
starts again. If the temperature stays below 6°C, the defrosting continues for 45 minutes.
The defrost water is collected in the channel under the evaporator from where it is led
through a tube down into the re-evaporation pan over the compressor.
76-504-0940
+ -
, then the display shows the current
+ -
is activated. Then the actual cabinet
15

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

K 400Kg 200Kg 400F 400F 200

Inhaltsverzeichnis