2
Positioning the heater - normal installation
DANGER! More than one heater can be installed in
!
the same sauna cabin.
Position the sauna heater:
on the same wall as the door (or the side wall if very close to
the door wall). The heater can also be positioned in a niche
(see Figure 3, Page 2).
at a safe distance from the floor, side walls and interior fittings
(see Figure 2, Page 2).
1
Figure 2: Positioning the heater - normal installation
1.
Minimum distance to side wall: 110 mm
2.
Minimum distance to ceiling: 1200 mm
3.
Minimum distance to interior fittings: 100 mm
4.
Minimum ceiling height: 1900 mm
5.
Minimum distance: 20 mm
6.
Minimum distance to interior fittings: 30 mm
7.
Distance to floor: 100 mm
Positioning the heater - niche installation
Position the heater at a safe distance from the floor, side walls
and interior fittings (see Figure 3, Page 2).
2
3
4
6
5
7
1
1
Figure 3: Positioning the heater - niche installation
1.
Minimum distance to side wall: 200 mm
2.
Max. 1000 mm
3.
Minimum distance to ceiling: 1200 mm
4.
Minimum distance to interior fittings: 100 mm
5.
Minimum ceiling height: 1900 mm
6.
Minimum distance: 20 mm
7.
Minimum distance to interior fittings: 30 mm
8.
Minimum distance to floor (without legs): 100 mm
Positioning the inlet vent
Position the inlet vent straight through the wall under the
centreline of the heater. Vent size for a family sauna approx. 125
cm².
Air circulation from the door must merge with the hot air from the
heater.
3
4
2
5
7
6
8