3) Adjustments
The NEOMAT tubular motors feature an electronic limit switch system, the electronic control unit interrupts the movement when the awning
reaches the set opening and closing positions. These positions must be programmed into the memory after the motor has been installed
and the awning mounted.
The motor can still be controlled even if these two positions, "0" (awning closed) and "1" (awning open), have not yet been memorised, how-
ever, the movement in this case will be hold-to-run. An intermediate position (Pos. "I") to partially open the awning can also be programmed.
The "I" position and the activation of the torque reduction (RDC) can also be programmed at a later date.
Awning completely closed
(Pos. "0")
The following can also be programmed:
• Position 2 necessary for the "FRT" function that keeps the fabric taught when the awning is fully open.
• The "FTC" function to automate awnings with an automatic hooking mechanism.
Position 2 for "FRT" function
4) Programming
The programming phase is divided into 3 parts:
1. Memorisation of the transmitters
2. Programming of positions "0" and "1"
3. Optional programming
The memorisation phases must be performed as indicated in table A1 to ensure that a transmitter can control a NEOMAT-T motor.
WARNING:
All the memorization sequences are timed, that is, they must be completed within the programmed time limits.
For transmitters with multiple "groups", choose the transmitter group the motor must be associated with before proceeding with the
memorization phase.
Programming via radio may be done on all the receivers within the range of the transmitter; therefore, only the one involved in the oper-
ation should be kept switched on.
It is possible to check if the motor already has transmitters memo-
rized; this is done by checking the number of beeps when the motor
is switched on.
Awning open (Pos."1")
"2"
"1"
Release position S for awnings that are kept taught by means of an
automatic hooking mechanism.
2 long beeps
2 short beeps
Intermediate position ("I")
Control of the memorized transmitters
No memorized transmitter
There are already transmitters memorized
RDC Torque reduction position
during closure
"0"
"A"
"S"