Herunterladen Inhalt Inhalt Diese Seite drucken

Performance History - Elcon ELCONNECT next BIG 10 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ELCONNECT next BIG 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIG 10 Router
TMP (total measurement period)
Full duration (time interval) of counting performance data; will be reset after 15 minutes =
900 seconds
ES (errored seconds)
number of seconds with errors
SES (severe errored seconds)
number of seconds with major alarms
CRC6 (cyclic redundancy check)
number of CRC6 errors
LOSW (los of sync word)
number of LOSW errors
UAS (unavailable seconds)
number of seconds without data transmission

3.9.4 Performance History

For line selection please click at line number above the table. The performance history shows
all errors which occurred in the 15-minute intervals over one day (24 hours).