Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - AEG MTH series Bedienung Und Installation

Hydraulisch gesteuerter, offener klein-durchlauferhitzer mit blankdrahtsystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

» Have the electrical safety of the appliance regularly
checked by an electrician.
» Regularly descale or replace the special aerator (see
chapter „Appliance description / Accessories").
6.

Troubleshooting

Problem
Cause
The appliance will not
No power to the ap-
start despite the DHW
pliance.
valve being fully open.
The aerator in the tap
is scaled up or dirty.
The water supply has
been interrupted.
If you cannot remedy the fault, notify your qualified con-
tractor. To facilitate and speed up your enquiry, please
provide the serial number from the type plate (000000 /
0000-00000).
MTH . . .
000000
Model:
E-Nr:
0000-00000
F-Nr:
Remedy
Check the fuses/
MCBs in your fuse
box.
Clean and/or descale
the aerator or replace
the special aerator.
Vent the appliance
and the cold water
inlet line (see chapter
"Settings").
Operation
31

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mth 350Mth 570Mth 440

Inhaltsverzeichnis