Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance - Cembre CPE-1 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für CPE-1:
Inhaltsverzeichnis

Werbung

ENGLISH
3.3) Storage
After completion of the work release the oil pressure by pressing the release push button
and make sure that the ram of the head connected is completely retracted.
– Switch off the pump by the ON-OFF switch (IG), selecting position "0".
– Disconnect the pump from the mains supply for long periods of inactivity.
4. WARNING
The pump is robust, completely sealed and requires very little daily maintenance.
Compliance with the following points should help to maintain the optimum performance
of the unit:
– Avoid dirty surfaces: dust and sand are a danger to any hydraulic equipment.
– The mains supply cable must be in perfect conditions and correctly installed other it
must be replaced immediately.
Should it be necessary to extended the mains cable, use 3 core (2 phases+earth) cable
of suitable section.
Never pull the cable to disconnect it from the mains supply.
Keep the cable may from heat, oil and sharp edges.
– Store the pump in a clean, dry environment.
4.1) High pressure fl exible hose
– Before using the pump, check that the fl exible hose and couplings are not damaged.
– Before disconnecting the hydraulic head from the hose, make sure that the ram is com-
pletely retracted.
– Do not bend or kink the hydraulic hose.
– Keep the pump and fl exible hose away from naked fl ames and sources of heat above
70°C.
– The factory fi tted spring steel, spiral guards must be in place at each end of the fl exible
hose.
– Do not touch the fl exible hose when under pressure.
– When using the pump, the fl exible hose must be uncoiled and laid out straight.

5. MAINTENANCE

Never open the electrical panel cover or effect any maintenance operation when
the pump is connected to the mains supply.
Should replacement of pump components be necessary, always use original spare
parts.
After every use, the pump and accessories must be wiped with a clean cloth, taking care
to remove any residue, especially around the sockets, quick couplers and inside the
protective caps.
It is possible to check working pressure with the MPC1 gauge available as an optional
accessory (see page 38).
FIG. 6
FIG. 7
7
36
TL
TV

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cpe-1-110Cpe-1-mgCpe-1-110-mg

Inhaltsverzeichnis