Insert the cable conduit with the aid of a wire
pull and connect to the socket.
With the versions with control unit, the special
cable (art. no. 28530) or the hose for pneuma-
tic level measurement (art. no. 25830) must
also be pulled through the cable conduit. Fill the
tank with water and check the function of the
floating switch and the probes and submersible
pipe. Set slotted cover or cover plate in place.

3.3 Servicing

Caution
Always REMOVE THE MAINS PLUG before
carrying out any work on the pump!
To do this, unscrew the suction strainer after re-
moving the pump, take the suction cover off
and clean the impeller space. Check the floa-
ting switch and level probes or submersible
pipe and alarm probe regularly for soiling and
clean if necessary.
Never open the pump yourself (always have an
expert do it) since improper handling could da-
mage the pump seal and allow oil to enter the
wastewater.
3. Cleaning and servicing
3.4 Servicing the integrated backwater
Remove the pump. After removal of the pump
valves
attachment (loosen the two cross-slot screws,
see Fig. 12), the backwater valve can be re-
moved and cleaned.
This allows unhindered access for cleaning the
pressure pipe.
Caution
During installation, make sure that the valve is
mounted with the arrow pointing downwards.
3.5 Use of the KTP 500 as submersible
Motor-driven submersible pumps contain oil for
pump
lubrication and cooling; this oil can escape and
soil the pumping medium if the pump is dama-
ged.
Before you put your KESSEL Aqualift S sub-
mersible pump into operation, have an expert
check whether the following electrical protec-
tive measures are available: grounding, neu-
tral, isolation transformer or residual current-
operated protective circuit; these must comply
with the requirements of local electricity sup-
35
pliers and be in perfect working condition.
(EVU = Energie-Versorgungsunternehmen =
electricity suppliers)
Caution
The electrical plug and socket device must be
kept dry! If there is a danger of flooding, install the
plug and socket device in the floodproof range.
Pumps may only be used in swimming pools
and garden ponds and their protected area if
they have been set up according to VDE 0100
§ 49d. Please ask your qualified electrician.