1. Ex marking / 2. Safety
The instruments are suitable for the requirements of the following areas:
Zone 1
Zone 2
Zone 21
Zone 22
Marking
II
2G
c
IIC
2. Safety

2.1 Intended use

The pressure measuring instruments described here are suitable for pressure measure-
ment in hazardous areas.
The non-observance of the instructions for use in hazardous areas can lead to the loss of
the explosion protection.
The model DPG40 with ATEX option is suitable for the following hazardous areas:
II 2G c IIC T4/T5/T6 X
II 2D c T85 °C/T100 °C/T135 °C X

2.2 Responsibility of the operator

The responsibility for classification of zones lies with the plant operator and not the
manufacturer/supplier of the equipment.
WIKA additional information Ex c for model DPG40
Designation
Significance
CE marking
Conformity markings in accordance with appendix X of
the ATEX directive. The manufacturer shall apply it before
placing on the market.
Instrument group
The unit may be used in hazardous areas, except within
the mining industry.
Instrument
With instrument category 2G, a potentially explosive
category
atmosphere involving gases (G) may occur occasionally.
The instrument ensures a high level of safety and can be
used in zone 1 and zone 2.
Ignition protec-
Constructive safety for non-electrical instruments in
tion type
hazardous areas in accordance with DIN EN 13463-5.
Instrument group
Electrical instrument group for gas hazardous areas in
accordance with DIN EN 60079-0.
EN
5