OPTIONAL:
if you connect the brown and black wires to
the control relays on your boiler, it will be switched off if the
water level rises too high in the unit.
ATTENTION:
The maximum current admissible for our
detection system is 0.5A.
To protect the electrical components in the
SANICONDENS
®
Plus, once the alarm has been triggered,
any water continuing to fill the tank comes out through the
overflow outlets in the cover.
7e
EXAMPLE OF AN INSTALLATION OF
A SANICONDENS
Plus: see fig.
®
8
STANDARDS
SANICONDENS
®
Plus conforms to the European directive
89/336/CEE on electrical safety.
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
9
DISASSEMBLY
If a breakdown occurs, any service on the unit should be
carried out by a qualified engineer. In particular the
replacement of the power cable.
Disconnect the electrical supply before carrying out
work on the unit.
7e
10

TROUBLESHOOTING

INSTRUCTIONS RESERVED SOLELY FOR
QUALIFIED PROFESSIONALS
Disconnect the electrical supply before carrying out any work.
FAULT DETECTED
PROBABLE CAUSES
• The pump does not start
• The pump is not
connected to the power
supply
• The unit is not level
• Power cut
• Float blocked
• Condensates inlet pipe
blocked
• The pump does not lift
• Non-return valve blocked
• Discharge pipe blocked
11
GUARANTEE
SANICONDENS
Plus SFA is guaranteed for 2 years for
®
parts and labour, subject to correct installation and use of
the unit.
ACTION NEEDED
• Plug in the unit
• Please check the unit
with a spirit level
• Check the mains voltage
• Clean the SANICONDENS
®
Plus tank
• Clean the SANICONDENS
®
Plus inlet pipe
• Clean the valve
• Clean the discharge pipe