5. INSTALLATION

Prior to commissioning, check the pump
for possible external damages (e.g.
transport damages) in order to prevent
accidents with electrical current.
• Pumping starts when the plug is plugged into
the socket.
• The inlet screen must not be clogged by mud
and/or fibrous media.
Even an automatically operating device,
such as a submersible pump, must not
be operated for a long period of time
without supervision.
Note: Place the pump in an initial water level of
at least 15 mm to allow priming.
6. MAINTENANCE
Disconnect the electrical supply
before carrying out work on the
unit!
Maintenance consists of checking and cleaning
the sieve :
- Turn over the pump
- Undo the screws
- Clean the sieve
- Reassemble sieve by following the opposite
procedure.
7. MALFUNCTIONS: CAUSE AND

TROUBLESHOOTING

Malfunction Cause
1. Motor
- Supply voltage
does not
missing or wrong
rotate
- Faulty connection
- Defective power
cable
- Impeller blocked
- Activated
motor protection
(overheating,
blockage, voltage
error or other defect)
- Float suspended
- Motor defective
2. Motor
- Impeller clogged or
rotates, but
worn
does not
- Discharge pipe
convey
clogged/hose kinked
- Sieve clogged
3. Feed
- Pump not properly
volume too
ventilated (air bubble
low
int the housing)
- Discharge pipe
dimensioned too
small
4. The pump
- Water too dirty
stops too
quickly
- Pump blocked
- Thermical
protection on
8. GUARANTEE
SANIPUDDLE FSP is guaranteed for 2 years for
parts and labour, subject to correct installation
and use of the unit.
5
UK
FR
Troubleshooting
- Check power
supply
- Correct
connection
- Replacement
(Customer
service)
- Clean
- Check, inform
customerservice
- Change the
position of the
pump
-Replacement
(Customer
service)
- Clean/Replace
- Clean/Remove
kinks
- Clean
- Remove air by
tilting the pump
- Min. diameter of
25mm
- Unplug and
clean
- Unplug and
cleanr
- Check the water
temperature (see
4. Technical data)

Werbung