8.0 Specifications

Luxmeters 93408 and 93421:
23°C ± 5°C at less than 80% rel. humidity
Ranges (93421):
Resolution display:
Ranges (93408) :
Resolution display:
Display:
Display error:
Temperature coefficient: < 1%/K
Measurement rate:
Temperature range:
Height above M.S.L:
Supply :
Battery life cycle:
Sensor:
Cable length:
Dimensions:
Sensor dimension:
Weight:
93408 only:
Analogue measurement
output:
Output impedance:
Maximum cable length : 3 m
0-20 lx, 0-200 lx, 0-2000 lx, 0-20000 lx
0.01 lx, 0.1 lx, 1 lx, 10 lx
0-200 lx, 0-2000 lx, 0-20000 lx,0-200000 lx
0.1 lx, 1 lx, 10 lx, 100 lx
1 /
3
digit, LCD
2
±(2% rdg + 3 digits)
approx. 2.5 measurements/second
0°C...40°C at 80% realtive humidity
up to 2000 m
battery 9V IEC 6LR61
approx. 200 hours
silicium photodiode (with cosinus correction)
approx. 1.5 m
135 x 72 x 33 mm
100 x 60 x 27 mm
approx. 250 g with battery
0.2 V DC corresponds to 0...100%
Ri > 10 kΩ