Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Replacement Parts/Accessories - FLORABEST FTS 1100 D4 Originalbetriebsanleitung

Schmutzwasser-tauchpumpe
Vorschau ausblenden Andere Handbücher für FTS 1100 D4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
G B
I E

Troubleshooting

Faults
Pump does not start
Pumps has no dis-
charge
Pump does not switch
off
Pump switches off after
a short period

Replacement parts/Accessories

Spare parts and accessories can be obtained at
Item
9 1
11
3
2 8
Causes
Mains voltage is not applied
Float switch (
switch
Buckled pressure hose
Trapped air in the pump cas-
ing
Float switch (
drop
Reduces pump performance,
through severely contami-
nated water and additions in
the water which produce a
grinding effect
Motor contactor disconnects
the pumps because of water
pollution that is too severe.
Water temperature too high,
motor contactor breaks
www.grizzly-service.eu
27
Description
8 m nylon cord
Remedies
7) does not
position
Repair point at which the line
is bent
Tip the pump underwater until
the air escapes
Set up pumps correctly on the
7) cannot
pit base
wear parts
Pull out power plug and clean
the pump as well as shaft
Note maximum water tem-
35
Product No.
911 3475
91102503

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis