Herunterladen Inhalt Inhalt Diese Seite drucken

Storage; Spare Parts Order; Waste Disposal And Environmental Protection; Troubleshooting - FLORABEST FTS 1100 B2 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für FTS 1100 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Any measures above and beyond these,
particularly opening the equipment, are
to be carried out by an electrician. In the
case of repairs, always contact our service
centre.

Storage

Keep the equipment clean, dry and out
of the reach of children.
Unscrew the bracket adapter (
for storage.

Spare Parts Order

Use the service address supplied to order
replacement parts (see page 13).

Troubleshooting

Faults
Pump does not start
Pumps has no dis-
charge
Pump does not switch
off
Flow rate insufficient
Pump switches off after
a short period
10)
Causes
Mains voltage is not applied
Float switch (
7) does not
switch
Buckled pressure hose
Trapped air in the pump cas-
ing
Float switch (
7) cannot
drop
Reduces pump performance,
through severely contaminated
water and additions in the water
which produce a grinding effect
Motor contactor disconnects
the pumps because of water
pollution that is too severe.
Water temperature too high,
motor contactor breaks
Waste Disposal
and Environmental
Protection
Be environmentally friendly. Return the tool,
accessories and packaging to a recycling
centre when you have finished with them.
Do not dispose of electrical appli-
ances as unsorted municipal waste,
use separate collection facilities.
Hand over the device at an utilization loca-
tion. The plastic and metal parts employed
can be separated out and thus recycled
use can be implemented. Ask our Service-
Center for details. Defective units returned
to us will be disposed of for free.
Remedies
Check mains voltage
Bring float switch into higher
position
Repair point at which the line
is bent
Tip the pump underwater until
the air escapes
Set up pumps correctly on the
pit base
Clean pumps and replace
wear parts
Pull out power plug and clean
the pump as well as shaft
Note maximum water tempera-
ture of 35°C!
GB
IE
11

Werbung

Kapitel

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis