Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Replacement Parts/Accessories - FLORABEST FTS 1100 C3 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für FTS 1100 C3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting

Faults
Pump does not start
Pumps has no dis-
charge
Pump does not switch
off
Flow rate insufficient
Pump switches off after
a short period

Replacement parts/Accessories

Spare parts and accessories can be obtained at
If you do not have internet access, please contact the Service Centre via telephone
(see "Service-Center" Page 12). Please have the order number mentioned below ready.
Item
Description
4
Floor plate
4a
Screw set for floor plate
9/10
Connector set (reducer, sealing ring, angle adapter)
11
8 m nylon cord
Causes
Mains voltage is not applied
Float switch (
7) does not
switch
Buckled pressure hose
Trapped air in the pump cas-
ing
Float switch (
7) cannot
drop
Reduces pump performance,
through severely contami-
nated water and additions in
the water which produce a
grinding effect
Motor contactor disconnects
the pumps because of water
pollution that is too severe.
Water temperature too high,
motor contactor breaks
www.grizzly-service.eu
GB
Remedies
Check mains voltage
Bring float switch into higher
position
Repair point at which the line
is bent
Tip the pump underwater until
the air escapes
Set up pumps correctly on the
pit base
Clean pumps and replace
wear parts
Pull out power plug and clean
the pump as well as shaft
Note maximum water tem-
perature of 35 °C!
Product No.
IE
CY
91103470
91103471
91103472
91103473
13

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis