INsTALLATIoN

Maintenance

Pairing/unpairing the wireless remote control at the
DCE 11/13 RC
1 Button for pairing and unpairing
2 Yellow LED illuminates when wireless remote control is
activated
f To start pairing the wireless remote control briefly press the
f
button. The yellow LED starts to flash. Now press key "1"
on the wireless remote control. A brief flashing of the LED
indicates that pairing was successful. The yellow LED then
extinguishes.
f To unpair the wireless remote control press the key for 5 sec-
f
onds. A brief flashing of the LED indicates that unpairing was
successful. The yellow LED then extinguishes.
Plug-in position of the wireless remote control for
DCE 11/13 RC
www.stiebel-eltron.com
15. Maintenance
1
Draining the appliance
2
For maintenance work or when there is a risk of frost, drain the
appliance as follows:
f Close the shut-off valve in the cold water inlet pipe.
f
f Open the draw-off valve.
f
f Undo the water connections on the appliance.
f
f Remove the appliance.
f
f Drain the appliance via the water connections (residual water
f
will remain in the appliance).
Appliance storage
f Store the dismantled appliance in a room free from the risk
f
of frost, as water residues remaining inside the appliance can
freeze and cause damage.
Cleaning or replacing the strainer/flow limiter
DCE 11/13
DCE 11/13 RC
DCE 11/13 H
1 Strainer
2 Flow limiter
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
WARNING Burns
Hot water may escape during draining.