  • DEUTSCH, seite 17
• Service temperature: from -10 to +55 °C at a relative
humidity below 90 %.
• Service temperature when used together with fan
SR 500 EX is -10 to +40 °C
Shelf life
The equipment has a shelf life of ten years from the date
of manufacture which can be established by examining
the date wheel at the top of the outer mask body.
6. Key to symbol
See user instructions
Date wheel
CE approved by
INSPEC International Limited
Relative humidity
<XX% RH
+XX°C
Temperature range
-XX°C
Material designation
>XX+XX<
7. Approval
The SR 200 with polycarbonate visor is approved in ac-
cordance with EN 136:1998, class 3.
The polycarbonate visor has been tested against
EN 166:2001, clause 7.2.2, class B.
The SR 200 with glass visor is approved in accordance
with EN 136:1998, class 2.
The SR 200 in combination with fan unit SR 500/SR 700 is
approved in accordance with EN 12942:1998, class TM3.
The SR  200 in combination with compressed air at-
tachment SR  307 is approved in accordance with
EN 14594:2005.
The SR 200 in combination with fan unit SR 500 EX is
approved in accordance with EN  12942:1998, class
TM3, ATEX Directive 2014/34/EU and the IECEx scheme.
Class 2 = Full face mask for general use.
Class 3 = Full face mask for special use, ex. smoke
diving equipment.
Class B = High speed particles with medium energy
impact.
The PPE Regulation (EU) 2016/425 type approval has
been issued by Notified Body 0194. For the ad dress, see
the reverse side of the user instructions.
The EU declaration of conformity is available at www.
srsafety.com
32
ATEX-codes:
II 2 G Ex ib IIA T3 Gb (SR 200 with PC visor).
II 2 G Ex ib IIB T3 Gb (SR 200 with glass visor).
II 2 D Ex ib lllC 21 T195°C Db (SR 200 with PC/
glass visor).
Key to ATEX markings:
Explosion protection mark.
II
Equipment group (explosive atmospheres
other than mines with fire damp).
2 G
Equipment category (2 = High level of
protection for Zone 1, G = Gas).
Equipment category (2 = High level of
2 D
protection for Zone 21, D = Dust).
Explosion protected.
Ex
Type of protection (Intrinsic safety).
ib
IIA
Gas group (Propane).
IIB
Gas group (Ethylene).
IIIC
Dust material group (zone with conductive
dust).
T3
Temperature class, gas (maximum surface
temperature +200°C).
T195°C Temperature class, dust (maximum surface
temperature +195°C).
Gb
Equipment Protection Level, gas (high
protection).
Db
Equipment Protection Level, dust (high
protection).
IECEx-codes:
Ex ib IIA T3 Gb (SR 200 with PC visor).
Ex ib IIB T3 Gb (SR 200 with glass visor).
Ex ib IIIC T195°C Db (SR 200 with PC/glass visor).
Key to IECEx markings:
Ex
Explosion protected.
ib
Type of protection (Intrinsic safety).
IIA
Gas group (Propane).
Gas group (Ethylene).
IIB
IIIC
Dust material group (zone with conductive dust).
T3
Temperature class, gas (maximum surface
temperature +200°C).
T195°C Temperature class, dust (maximum surface
temperature +195°C).
Equipment Protection Level, gas (high
Gb
protection).
Db
Equipment Protection Level, dust (high
protection).
Type approvals in accordance with ATEX Directive and
IECEx Scheme have been issued by Notified Body No.
0470. NEMKO AS, Gaustadalléen 30, N-0314 Oslo,
Norway.
Australian StandardsMark
The full face mask SR 200 is tested and certified to
comply to AS/NZS 1716:2012. The StandardsMark is
issued under licence by SAI Global Pty Limited LIC No.
766 (ACN 108 716 669) ("SAI Global").