Grease layer thickness measuring device Multi Control
Installation of free-standing separators
3.2 Preliminary work
3.2.1 Open installation opening
Drill out the bottom of the threaded hole (maximum Ø 35 mm) or remove sealing plug.
3.2.2 Adjust measuring rod
Due to differing designs, materials and nominal sizes there are varying adjustable heights for
the measurement range. The following values should be used for ACO Building Drainage grease
separators for free-standing installation.
Release the knurled nut of the
compression fitting
Move the compression fitting to setting
level X on the setting scale.
Then retighten the knurled nut by hand.
50/ 72
Grease separator
Design
Material
round
Stainless steel
round
Stainless steel
round
Stainless steel
round
Polyethylene
round
Polyethylene
round
Polyethylene
round
Polyethylene
oval
Stainless steel
oval
Stainless steel
oval
Stainless steel
Polyethylene
oval
Polyethylene
oval
oval
Polyethylene
oval
Polyethylene
Chapter 3.1 "Connection openings"
Nominal size/NS
2 and 4
7 and 10
15 and 20
2 and 4
7 and 10
15
20
1
2, 3 and 4
5.5; 7; 8.5 and 10
1, 2, 3 and 4
5.5; 7; 8.5 and 10
15 and 20
25 and 30
850
4
3
2
1
800
9
8
7
6
5
4
3
2
1
700
9
8
7
6
5
4
3
2
1
600
9
8
7
6
5
4
3
2
1
500
Setting level X
[mm]
530
710
830
560
710
830
830
650
540
670
630
720
760
860
7
6
5
4
3
2
1
600
9
8
7
6
5
4