Switching on / Switching off (P)
The Air Flo switches on automatically when the power connection is established.
Switching on: Plug the shock-proof plug (44) of the 230 V unit in the shock-proof socket. Plug the CEE plug (46) of
the 400 V unit in the CEE socket.
Switching off: Pull the power plug (44) / CEE plug (46).
The control box (42) and the motor (overload) protection switch (43) are intended to protect the motor. The pump will
be switched off in the case of an overload.
Button (45): Press the button to restart the motor.
Red switch (47): Press the switch to trigger the motor (overload) protection switch. The motor will switch off.
Green switch (48): Press the switch to restart the motor.
Also read the section "Remedy of faults".
Cleaning
Disconnect the power plug (Figure P, 44/46) prior to starting cleaning work!
If necessary, clean the unit under clear water using a soft brush.

Remedy of faults

Attention! Danger emanating from the propeller rotating at high speed.
Possible consequences: Severe injury to limbs.
Protective measures: Disconnect the power plug (Figure P, 44/46) prior to starting work at the unit!
Malfunction
Pump does not start
Pump switches off after a short running period
Incorrect propeller rotational direction of the
400 V unit
Irregular water image effect, loud flow noise
Switch on the unit
Air Flo, 230 V: Allow the unit to cool down (approx. 30 seconds), then press the button (45) at the control box (42).
Pump will start.
Air Flo, 400 V: Press the green button (48) at the motor (overload) protection switch (46). Pump will start.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
14
Cause
No mains voltage
Pump overload
 Excessively soiled water
 Water temperature too high
 Filter basket soiled
 Propeller seized up due to soiling
 Motor defective
Mains phases in the CEE socket reversed
Filter basket soiled
Remedy
Check mains voltage
Clean, check supply lines
Clean filter basket
Only operate the unit at the water temperature
specified in the technical data
Clean the filter basket under running water us-
ing a brush.
Remove soiling
Contact OASE
Ensure that the propeller rotates counter-clock-
wise (CCW). Connect the mains phases in the
CEE socket to comply with the rotational direc-
tion.
Clean filter basket