7

Remedy of faults

Malfunction
No water jet emerges
Water emerges from the nozzle
uncontrolled
Jet length shortens
The water jet contours seem
diffused, jet loses its crystal clear
appearance
Lighting has failed
8

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
► Prior to reaching into the water, switch off the mains voltage to all units used in the water.
► Switch off the mains voltage prior to carrying out work on the unit.
The cleaning intervals depend on the water quality. Clean filter and screen of the Jumping Jet Rainbow
Star as soon as the quality of the water jet diminishes.
Cleaning filter and screen (Fig. L – S)
1. Remove the locking screw (41) using an Allan key (18).
2. Turn the hood (40) counter-clockwise against the stop and lift off.
3. Lift the cover (42) and remove the O ring (43).
4. Turn the cover (42) upside down and suspend it on a pin at the container (44).
Important: Do not pull on the cables, otherwise they will be damaged.
5. Take the filter (4) including screen (45) out of the container.
6. Pull the filter (4) out of the screen (45) and carefully wash both.
7. If necessary, remove and clean the diffusor plate (46).
8. Reassemble filter (4) and screen (45) in the reverse order and reinsert into the container (44).
9. Place the O ring (43) on the rim of the cover (42) (Fig. V), then press the cover (42) uniformly onto the
container (44).
The O ring (43) is a roll ring that only adopts its final position when the cover (42) is put into place.
10. Remove the lugs of the two connection cables (47). To this effect, push the connection cables (47)
back into the cable duct at the container (44).
11. Place the hood (40) onto the container (44). Ensure that the contour of the cover (40) and that of the
container (44) are offset in relation to each other. Subsequently, turn the hood (40) clockwise up to
the stop.
12. Retighten the locking screw (41) using an Allan key (18).
22
Cause
The Jumping Jet Rainbow Star is too deep
in the water
Pump power plug not connected
The jet diaphragm not centred around the
water jet
The water does not pass the centre of the
jet diaphragm
Filter and screen are clogged
The filter basket of the pump is soiled.
The Jumping Jet Rainbow Star is too deep
in the water
Water jet is torn apart by strong wind
Filter and screen are clogged
Pump takes in air
Default DMX programming
The LED of the spotlight is defective
Remedy
Adapt unit to the water depth
Connect unit to the power supply
Adjust the jet diaphragm such that the water
jet can pass unhindered
Adjust the jet diaphragm such that the water
jet can pass unhindered
Clean filter and screen
Clean filter basket
Adapt unit to the water depth
Clean filter and screen
Check the pump immersion depth
Change programming
Contact the OASE service