Herunterladen Inhalt Inhalt Diese Seite drucken

Remedy Of Faults - Oase AquaMax Eco 5000 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für AquaMax Eco 5000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

- EN -

Remedy of faults

Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running time
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
 Thoroughly clean the unit, check it for damage and replace any damaged parts.
 Protect electrical connections from moisture and dirt.
 Store the pump submerged and in a frost-free environment.
 Protect open plug connections from moisture and dirt.
Wear parts
 Impeller unit
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regu-
lations.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
 Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
10
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Excessive loss in the supply hoses
Excessively soiled water
Water temperature too high
Remedy
Check mains voltage
Clean/check supply lines
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Clean pump
Note maximum water temperature of +35 °C

Werbung

Inhaltsverzeichnis
loading