Herunterladen Inhalt Inhalt Diese Seite drucken

Operating And Display Elements; Led´s - Feig Electronic OBID ID ISC.MR200-EP Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
OBID i-scan
4

Operating and Display Elements

4.1 LED´s
Table 4-1 shows the configuration of the LED's.
Name
"RUN"
LED V1 (green)
"HF"
LED V2 (blue)
"Host"
LED V3 (yellow)
"Diag.2"
LED V4 (yellow)
"Diag.1"
LED V5 (red)
Table 4-1: LED configuration
FEIG ELECTRONIC GmbH
Montage / Installation
(Operation indicator)
-
Indicates proper running of the internal Reader software
Flashing frequency approx. 1 Hz
-
(RF communication / EEPROM status)
Short flashing indicates communication with a transponder on
-
the RF interface
Flashes alternately with V1 after the reset following a software
-
update
-
Flashes alternately with V1 if an error in reading the
parameters occurred following a reset
(Host communication)
-
Short flashing indicates a protocol is being sent to the host.
(for future applications)
(Reader initializing / RF warning)
Comes on during Reader initializing following power-on or after
-
a reset.
Comes on when there is a warning in the RF section of the
-
Reader.
The error type can be read via software using the Reader
Diagnostic command [0x6E].