OBID i-scan
3.8 Supply voltage
Connect the 12-24 VDC supply voltage to Terminal X1.
The cable length between the power supply and the Reader module must not exceed 3 m.
Terminal
Abbreviation
X1 / Pin 1
X1 / Pin 2
Table 3-4: Supply voltage pin assignments
Note:
•
Reversing the polarity of the supply voltage may destroy the unit.
The power supply should be a Safety Extra-Low Voltage (SELV) type with limited power. The
output power of the power supply should be at least 15 watts.
Output voltage
Output power
Table 3-5: Electrical specifications for external power supply
FEIG ELECTRONIC GmbH
Montage / Installation
Vcc
Vcc – supply voltage (+)
GND
Ground – supply voltage (-)
ID ISC.MR200
Fig. 3-8: Connecting the supply voltage
12 - 24 V
≥ 15 W
Page 39 of 53
Description
X1
1
Vcc
2
GND
DC
ID ISC.MR200-W/EP
M50808-4de-ID-B.doc