Operating and Display Elements

3.1 LEDs

Table 3-1 shows the LED configuration.
Abbreviation
LED V1 (green)
LED V2 (blue)
LED V3 (yellow)
LED V4 (yellow)
LED V5 (red)
LED V6 (green)
(only device
version with ACC)
Table 3-1: LED configuration
FEIG ELECTRONIC GmbH
Installation
"RUN-LED 1"
Indicates proper running of the internal Reader software (DSP)
-
Diagnostic 1: RF communication / EEPROM status
Short flashing indicates errorless communication with a
-
transponder on the RF interface
-
Flashes alternately with V1 after a reset following a software
update
-
Flashes alternately with V1 in case of a data error when
reading the parameters after a reset
Diagnostic 2: Host communication
-
Short flashing indicates sending of a protocol to the host on the
RS232/RS485 interface
Reserved
Diagnostic 4: RF warning
-
Comes on during Reader initialization after power-on or after a
reset.
-
Comes on when there is an error in the RF section of the
Reader. The error type can be read out via software over the
RS232/RS485 interface
"RUN-LED 2"
Indicates proper running of the AC Controller
-