installation dimensions
20
Ventilation
The electronics in the appliance need
cooling. The appliance will
automatically switch off if there is
insufficient air circulation. There are
ventilation openings on the underside
of the appliance. It must be possible
for cool air to be drawn in through
these openings. There are outlet openings on the underside and at the front of
the appliance.
Several alterations must be made to the kitchen unit to allow optimal
ventilation of the hob.
Above a door, drawer of fixed panel
Ventilation occurs through the plinth and back of
the cupboard. Saw out the ventilation openings
2
(min 100 cm
).
Make sure the crossbar does not impede the
airflow. Plane or saw the crossbar D diagonally if
necessary.
Do not allow a drawer to block the ventilation
openings on the bottom of the appliance.
If there is a drawer under the hob, a gap of at
least 560 x 6 mm should be made at the front.
The distance between the draw A and the hob
should be at least 10 mm.