6.1 Equipping the TIG welding torches
CAUTION
Risk of injury
Through-hole or puncture caused by sharpened electrode tip.
• Do not reach into the danger zone.
• Wear protective gloves.
®
6.1.1 ABITIG
MT 200/300W
1
Setting gauge
2
Electrode holder
3
Adapter
Fig. 1
Equipping the ABITIG
1 Insert the electrode holder (2) into the adapter (3) from the front.
2 Slide tungsten electrode (4) from the front through the adapter (3) into the guide tube (5).
3 Screw electrode holder (2) containing the tungsten electrode (4) into the guide tube (5) but
do not tighten.
4 Set the length x using the setting gauge (1).
The length x depends on the welding task.
5 Tighten electrode holder (2).
6 Screw pre-mounted unit (6) into the torch body (7) as far as it will go.
7 Screw in gas nozzle (8).
BAL.0107 • 2018-11-12
1
2
x
8
4
Tungsten electrode
5
Guide tube
6
Pre-mounted unit
®
MT 200/300W
4
3
7
7
8
6 Putting into operation
5
6
Torch body
Gas nozzle