Installation Guide

Installation

Optional
installations
VIMCG20F / 088N3678
Danfoss Icon™ Master Controller 24 V
If wired installation
Note! Disconnect power before wiring!
For wiring of wired thermostats and actuators,
please refer to the Quick Guide sections B and C.
24V Thermostats can be wired either in BUS or Star
configuration, see below.
The system is not polarity sensitive.
If BUS wiring (serial)
THERMOSTAT
A
B
NTC
2
Next
Thermostat
max. 0.75 mm
If Star wiring (parallel)
THERMOSTATS
A
B
NTC
Installation of App Module,
code no. 088U110
The App Module is required, when app function-
ality is wanted. For inclusion in a wireless network
(Wi-Fi), please refer to the App Module installation
guide. In systems with more Danfoss Icon™ Master
Controllers only one App Module is required, and
it can be added to any of the Master Controllers.
Wiring a pump
PWR1 output is intended for usage in installations
where a circulation pump is present in the system.
The PWR1 output has a live 230 V output (max. 100
W), which is activated when heat is demanded by
at least one thermostat. When no heat is demand-
ed from any thermostat the PWR1 output will be
turned off to save energy.
When heat is demanded the output will be acti-
vated with a delay of 180 sec. to prevent the pump
from running without being able to generate flow
due to the delay on the actuators in the heating
circuits.
Wiring a potential free relay
A potential free relay can be used e.g. to activate
heat demand/production from a boiler.
It is recommended to use the potential free relay
as heat demand signal for all boilers with appropri-
ate inputs available.
For boilers with 0-10 V modulation it is not
possible to use the heat demand signal from the
Danfoss Icon™ Master Controller 24V.
Please note that some combi-boilers may have hot
water prioritization, which can cause heat produc-
tion of the system to be delayed.
If wireless installation
Note! Disconnect power before wiring!
Connect a Radio Module, code no. 088U1103.
The Radio Module is required, when wireless ther-
mostats are installed. The radio module is supplied
with a 2m patch cable. A longer cable (max. 15m)
can be used if necessary.
One Radio Module must be fitted to each Danfoss
Icon™ Master Controller 24V in systems with more
THERMOSTAT
Master Controllers.
A
B
NTC
To Master
Controller
2
As a special feature, it is possible to include wired
thermostats in a wireless system.
NTC
A
B
For installation of wireless thermostats and
2
actuators, please refer to the Wireless Quick Guide
max. 1.5 mm
2
sections B2, B3, B4 and C1.
Installation of Expansion Module,
code no. 088U1100 (Quick Guide E4).
Note! Disconnect power before inserting the Ex-
pansion Module.
Slide of the cover and insert the Expansion Mod-
ule. Follow the supplied instructions.
Note! If an Expansion Module is added to a system
with multiple Master Controllers, it must be installed
on the System Master.
Installation of a Floor Sensor (if 24V thermo-
stat), code no. 088U1110.
For installation of a floor sensor, please refer to
instructions supplied with the thermostat.
Rooms with both floor heating and radiators
controlled by one thermostat.
It is possible to have a mixed application with both
radiators and floor heating controlled by the same
Danfoss Icon™ room thermostat, if
• The thermostat has a floor sensor set up for
"dual mode" on the thermostat (set "DU" mode
in installer menu on thermostat).
• The radiator has it's flow controlled by an actu-
ator.
• Remember to set correct emitter type for rele-
vant outputs in said room.
In this application, the floor sensor is only used
to assure a min. floor temperature (if necessary, a
max. floor temperature can be set).
The built-in sensor is used to control the room
temperature by the assigned radiator output (the
fastest of the two output types).
Note! Only Danfoss Icon™ room thermostats with
floor sensor are supported.
088U1103
© Danfoss | FHEC | 2017.12 | 7
GB