18 Troubleshooting

18 Troubleshooting

18.1 Troubleshooting Trimmer or Charging Cable

Condition
LEDs on trimmer
Trimmer does not
1 LED flashes
start when switched
green
on.
3 LEDs glow red
3 LEDs flash red. There is a electrical
Trimmer cuts out
3 LEDs glow red
during operation.
Trimmer runtime is
too short.
Trimmer is not being
3 LEDs glow red
charged.
0458-718-9621-A
Cause
Trimmer has low charge.
Trimmer is too hot.
malfunction.
The trimmer is damp.
Trimmer is too hot.
There is a electrical
malfunction.
The trimmer is not fully
charged.
Normal trimmer life has
been exceeded.
Trimmer is too hot.
Malfunction in trimmer or
charging cable.
Remedy
► Recharge the trimmer.
► Remove the activation key.
► Allow trimmer to cool down.
► Remove the activation key.
► Do not use your trimmer and contact your STIHL
servicing dealer.
► Allow the trimmer to dry.
► Remove the activation key.
► Allow trimmer to cool down.
► Switch off the trimmer, wait 5 seconds and then
switch on again.
► Fully charge the trimmer.
► Replace the trimmer.
► Remove the activation key.
► Allow trimmer to cool down.
► Remove the activation key.
► Contact your STIHL servicing dealer.