13. DC-ADAPTER INPUT: connect the supplied DC-adapter here.
14. POWER SWITCH: used to switch the controller on/off. The last working status is preserved, last active
scenes will start automatically when you switch the Scenemaster back on.
CONNECTIONS
SIMPLE DMX-CONNECTION
Simply connect the DMX-output of the controller to all kinds of
DMX-controllable equipment. The Scenemaster controls DMX-
channels 1 to 16. To obtain more DMX-channels, just link
several controllers together (see below).
SIMPLE MIDI-CONNECTION
Simply connect the USB-output of the controller to a PC. No
drivers needed, these will be automatically installed.
Don't forget to set the controller to one of the 16 available
MIDI-channels. See chapter "HOW TO USE" to learn more
about using MIDI on the Scenemaster. To obtain more channels, just link several controllers together (see
below).
LINKING SEVERAL UNITS TOGETHER
If 16 channels and/or scenes is not enough for your
application, don't worry: you can link several units together.
The drawing shows the maximum of 4 units but you can also
use the following combinations:
 2 units: 1master + 1slave = 32 scenes + channels.
 3 units: 1master + 2slaves = 48 scenes + channels.
 4 units: 1master + 3slaves = 64 scenes + channels.
Linking the units is very easy: just use standard RJ-45 cat5
patch cables as used in Ethernet computer networks. (we also
supply these cables: 0,5m = order code 5151 or 1,5m = order
code 5152).
 Switch the controllers off.
 Connect the link output (11) of the master to the link input
st
(11) of the 1
slave.
 Connect the link output (11) of the 1
input (11) of the 2
 Connect the DMX-cable to the DMX-output (12) of the master (!!!).
 Switch the controllers on: the controllers will link automatically, on the left of each display you will see
the "unit ID"-number. The master has always unit ID = 1.
Important remark: the controls numbered 4 to 9 on the front panel drawing can ONLY be used on the
master unit, on the slaves these controls are NOT used! (just imagine they are not on the slave units)
HOW TO USE - AS DMX-CONTROLLER
USE IN MANUAL MODE
The simplest way to use the Scenemaster:
 Press the SCENE/MANUAL button (4) to switch the controller to manual mode.
 Open the master fader (7).
 Use the CHANNEL faders (1) and FLASH buttons (2) to create the desired output.
Remark: use the DISPLAY button (6) to show the desired DMX-values on the display (0-512 or 0-100%).
JB SYSTEMS
®
st
nd
slave. (if needed you can go up to 4 units.)