Removing and installing a control card
Please.only.use.the ELS Professional Card
Before.replacing.a.control.card,.switch.the.entire.door.control.off.and.open.the.cover.of.the.control.
housing.
Caution
The regulations for handling elements with an electrostatic risk must be complied
with.
The ELS Professional Card 3.1 should only be operated in connection with a safety
edge. It is possible that safety devices are bypassed upon delivery. When retro-
fitting the ELS Professional Card 3.1, please ensure that there are no forbidden
bypasses.
Carefully.remove.the.control.panel.mounted.on.slot.J3/J4 and.insert.the.new.control.panel.in.slot.
S80
J3/J4.on.the.right.on.the.
Ensure.that.the.panel.is.correctly.oriented!
Caution
The control unit may only be connected by an electrician.
Observe the relevant VDE standards.
During all installation work the equipment must always be disconnected from the mains.
When connecting, refer to the specifications of the S80. Always observe the maximum connection figures
indicated.
Installing the Mains Connection
The.working.voltage.of.the.S80.door.control.unit.is.3-phase.400.V/230.V,.50.Hz.(L1,L2,L3,N,PE)..To.connect.up.to.the.mains,.
install.a.mains.cable..of.approx..1.2.m.length.with.a.CEE.16.A/6H.plug.and.a.CEE.16.A/6H.socket.below.the.control.unit.so.that.
the.plug.is.readily.accessible..Alternatively,.connect.the.control.unit.via.a.non-detachable.installation.cable.complete.with.local.
isolation.(see.position.of.the.terminals.and.components.as.well.as.the.wiring.diagram).
Note
If a non-detachable connection is made, a local isolation facility has to be integrated into the mains lead
or directly into the S80 control unit. Protect the mains lead for the control unit with a 3-phase AC auto-
matic cut-out (3 x 16 A).
Connecting the Drive to the Control Unit
The.drive.cable.is.usually.already.attached.to.the.control.unit..If.not,.connect.the.12-core.drive.cable.to.terminals.E.and.PE.in.
accordance.with.the.wiring.diagram..The.11.black.wires.of.the.drive.cable.are.numbered.1.to.11,.corresponding.to.the.numbers.
of.terminals.E..The.green/yellow.earth.wire.must.be.connected.up.to.one.of.the.3.PE.earth.terminals.( ).
28
3.1
for.operating.drives.with.electronic.limit.switching.
.basic.panel,.as.shown.opposite.
Electrical connection