With the IR 180 AP and
sensor technology switches
HF 360 AP Sensor
the light on automatically on
Switches, groping for the
entering the detection zone
light switch is finally a thing
and off again after the pre-
of the past! The intelligent
set time. This is not only ex-
IR 180 AP:
Angle of coverage: 180°
The IR 180 AP is equipped
with a pyro sensor which
HF 360 AP:
Angle of coverage: 360°
The HF 360 AP is an active
motion detector. It reacts -
independently of tempera-
ture - to the slightest move-
ment. The integrated HF
14
tremely convenient, but also
increases safety and is en-
ergy and cost saving.
detects the invisible heat
emitted by moving objects
(pedestrians, animals etc.).
8 m
The heat thus detected is
max.
electronically converted and
switches on connected
consumers (e.g. a light). No
heat radiation is detected
through obstacles, such as
walls or glass and no
switching therefore occurs.
sensor transmits high fre-
quency electromagnetic
waves (5.8 GHz) and re-
8 m
ceives their echo. In re-
max.
sponse to the slightest
movement in the detection
zone, the change in echo
is perceived by the sensor.
A microprocessor subse-
quently triggers almost with-
out delay the switching
command „light on". Detec-
tion is possible through
doors, panes of glass or
thin walls.

Technical specifications

IR 180 AP:
Dimensions (H x W x D):
82 x 72 x 67 mm
Output:
max. 1000 W (ohmic load, e.g. filament bulb)
max. 500 VA (uncompensated, inductive, cos ϕ = 0.5
Connection:
230 V, 50 Hz
3-lead connection (L, L', N)
Contact gap:
, contact clearance of less than 1.2 mm between the
contacts when unit is switched off.
Installation height:
approx. 1.1 and 2.2 m*
Sensor technology:
Infrared sensor
Transmission output:
-
Angle of coverage:
180° with
90° angle of aperture
Reach:
8 m max.
Twilight setting:
2 - 2000 lux
Time setting:
10 sec. - 30 min.
Permanent light:
switchable (4 h)
Permanent light OFF:
switchable
Type of enclosure:
IP 54
* Installation above a door
HF 360 AP:
82 x 72 x 64 mm
e.g. fluorescent lamps)
approx. 1.1 and 2.2 m*
5.8 Ghz
High frequency
approx. 1 mW
360° with
140° angle of aperture
1 - 8 m
continuously adjustable
2 - 2000 lux
10 sec. - 30 min.
switchable (4 h)
switchable
IP 54
15