Technical specifi cations
IR 180 UP:
Dimensions:
(H x W x D) 80 x 80 x 55 mm
Output:
Filament bulbs, 1000 W max., operating on 230 V AC
Fluorescent lamp, 500 W max., at cos ϕ = 0.5,
inductive load at 230 V AC
4 x 58 W each max., C ≤ 88 μF
operating on 230 V AC
Connection:
230 V, 50 Hz
3-lead connection (L, L', N)
μ, contact clearance of less than 1.2 mm between the
Contact gap:
contacts when unit is switched off.
Installation height:
approx. 1.1 + 2.2 m
Sensor technology:
Infrared sensor
Transmission output:
-
Angle of coverage:
180° with 90° angle
of aperture
Reach:
max. 8 m
Twilight setting:
2 - 2000 lux
Time setting:
10 sec. - 30 min.
Permanent light:
switchable (4 h)
Permanent light OFF:
switchable
Orientation light:
-
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast
(total capacity of all connected ballasts below the value specifi ed).
*2)
Installation above a door.
HF 360 UP:
NF 50 UP:
*1)
*2)
*2)
approx. 1.1 m
approx. 1.1 + 2.2 m
5.8 Ghz
5.8 Ghz
High frequency
High frequency
approx. 1 mW
approx. 1 mW
-
360° with 140° angle
of aperture
approx. 5 cm
1 - 8 m
continuously adjustable
-
2 - 2000 lux
-
10 sec. - 30 min.
-
switchable (4 h)
switchable
-
red LED
-
- 16 -
Installation
Note for IR 180 UP:
conductor (N) are connected
The installation position
to the terminal block. A pro-
should be at least 1 m from
tective-earth conductor is
a light, since heat radiation
not required.
may trigger the system.
Important: Reversing the
Installation procedure:
connections may result in
1. Pull the mains lead out
damage to the unit.
of the fl ush box and strip
the insulation from the
2. Push the basic element
individual leads.
and arrange horizontally.
Connecting the supply
Take care that the cables
lead (refer to Ill. on page 5)
are not pinched. Tighten
The mains lead consists of a
both screws on the ex-
3 phase cable.
pansion claw until the
L = phase conductor (usu-
basic element is fi rmly
ally black or brown)
seated or screw with
N = neutral conductor
socket fi xing screws on
(usually blue)
the support ring.
L' = phase conductor (usu-
3. Apply the cover frame
ally black or brown)
and surround
If in doubt, the cable must
carefully mount the sen-
be identifi ed with a voltage
sor unit
tester. Switch OFF the cur-
4. Once the mains connec-
rent again. Phases (L) and
tion has been made, the
(L') in addition to the neutral
sensor switch can be op-
Functions
Contact-free switching
Move your hand in front of
the sensor unit at a distance
of max. 5 cm and the
connected light will switch
ON.The procedure is equally
simple when switching OFF.
(IR 180 UP / HF 360 UP / NF 50 UP)
erated (refer to Functions
section).
Only IR 180 UP and
HF 360 UP:
The adjustment controls for
the functions are concealed
behind the folding design
shade. Push in the catch on
the sensor unit with a screw-
into the fl ush box
driver and fold the design
shade forwards.
Note:
Parallel switching of
IR 180 UP and HF 360 UP
is possible. Nevertheless, a
neutral lead must be pres-
ent on each fl ush box. The
max. output to be switched
does not increase as a
and
result.
without tilting.
(only for NF 50 UP)
Orientation light
The Sensor Switch NF 50 UP
is equipped with a red LED.
This serves as an orientation
light in the dark, so that the
switch is easier to fi nd.
Note:
Parallel switching or ex-
change of an existing two-
way circuit is not possible.