Inverter
Rated power
Mains voltage range
Rated mains current
without mains choke
with mains choke
Output current
2 kHz
4 kHz
8 kHz
16 kHz
Power loss
Overcurrent cycle 180 s
Max. output current
Overload time
Recovery time
Max. output current
during the recovery time
Overcurrent cycle 15 s
Max. output current
Overload time
Recovery time
Max. output current
during the recovery time
Brake chopper
Max. output current
Min. brake resistance
Motor cable length
shielded, without EMC
C2 residential area /
industrial premises
Weight
kW
A
A
A
A
A
A
W
A
s
s
A
A
s
s
A
A
Ω
m
m
kg
3-phase mains connection 480 V
I55AE322F
22
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
47.4
35.3
40.4
40.4
40.4
26.9
668
60.6
60
120
30.3
80.8
3
12
30.3
52
15
100
20
10.3
Technical data
Rated data