use abrasive cleaning agents, thinners or benzene for cleaning and
never immerse the device in water or other cleaning liquids. Take
care not to scratch the surface of the sensor lens and the display.

11. Battery Replacement

This device is supplied with one lithium battery, type CR2032. The
battery needs replacing when only the «» icon BM is shown on
the display.
Remove the battery cover BP by sliding it in the direction shown.
Insert the new battery with the + at the top.
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.

12. Guarantee

This device is covered by a 5 year guarantee from the date of
purchase. The guarantee is valid only on presentation of the guar-
antee card completed by the dealer (see back) confirming date of
purchase or the receipt.
• The guarantee covers the device. The battery and packaging
are not included.
• Opening or altering the device invalidates the guarantee.
• The guarantee does not cover damage caused by improper
handling, a discharged battery, accidents or non-compliance
with the operating instructions.
Please contact Microlife-service.

13. Technical Specifications

Type:
Ear Thermometer IR 150
Measurement
range:
0-100.0 °C / 32-212.0 °F
Resolution:
0.1 °C / °F
Measurement
Laboratory:
accuracy:
±0.2 °C, 32.0 ∼ 42.2 °C
±0.4 °F, 89.6 ∼ 108.0 °F
Display:
Liquid Crystal Display, 4 digits plus special icons
Acoustic:
The unit is turned ON and ready for the measure-
ment: 1 short beep.
Complete the measurement: 1 long beep.
System error or malfunction: 3 short beeps.
Fever alarm: 10 short beeps.
IR 150
Memory:
30 readings recall in the memory mode with a
record of both time and date.
Backlight:
The display light will be GREEN for 1 second,
when the unit is turned ON.
The display light will be GREEN for 5 seconds,
when a measurement is completed with a reading
less than 37.5 °C / 99.5 °F.
The display light will be RED for 5 seconds, when
a measurement is completed with a reading equal
to or higher than 37.5 °C / 99.5 °F.
Operating
10 - 40 °C / 50.0 - 104 °F
conditions:
15-95 % relative maximum humidity
Storage
-25 - +55 °C / -13 - +131 °F
conditions:
15-95 % relative maximum humidity
Automatic
Approx. 1 minute after last measurement has been
Switch-off:
taken.
Battery:
1 x CR2032 battery 3V
Battery
lifetime:
approx. 1000 measurements (using a new battery)
Dimensions: 139 x 39 x 42 mm
Weight:
54.5 g (with battery), 51 g (w/o battery)
IP Class:
IP22
Reference to
EN 12470-5; ASTM E1965;
standards:
IEC 60601-1; IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected
service life:
5 years or 12000 measurements
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
According to the Medical Product User Act a biennial technical
inspection is recommended for professional users. Please
observe the applicable disposal regulations.

14. www.microlife.com

Detailed user information about our thermometers and blood pressure
monitors as well as services can be found at www.microlife.com.