Herunterladen Inhalt Inhalt Diese Seite drucken

Atex Iecex - WIKA RTD Zusatzinformation

Für explosionsgefährdete bereiche (ex i)
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. Ex marking
For applications without transmitters (digital displays) that require group II instruments
(potentially explosive gas atmospheres), the following temperature class classification and
ambient temperature ranges apply:
Table 1
Marking
ATEX
IECEx
II 1G
Ex ia IIC T1, T2 T3,
T4, T5, T6 Ga
II 1/2G Ex ia IIC T1, T2, T3,
T4, T5, T6 Ga/Gb
II 2G
Ex ia IIC T1, T2, T3,
T4, T5, T6 Gb
II 2G
Ex ib IIC T1, T2, T3,
T4, T5, T6 Gb
For applications requiring instruments of equipment group II (potentially explosive dust
atmospheres), the following surface temperatures and ambient temperature ranges apply:
Table 2
Marking
ATEX
IECEx
II 1D
Ex ia IIIC T65 °C Da
II 1/2D Ex ia IIIC T65 °C Da/Db
II 2D
Ex ia IIIC T65 °C Db
II 2D
Ex ib IIIC T65 °C Db
II 1D
Ex ia IIIC T95 °C Da
II 1/2D Ex ia IIIC T95 °C Da/Db
II 2D
Ex ia IIIC T95 °C Db
II 2D
Ex ib IIIC T95 °C Db
II 1D
Ex ia IIIC T125 °C Da
II 1/2D Ex ia IIIC T125 °C Da/Db
II 2D
Ex ia IIIC T125 °C Db
II 2D
Ex ib IIIC T125 °C Db
When there is a built-in transmitter and/or a digital display, the special conditions from
the type examination certificate (see chapter 4 "Special conditions of use (X conditions)")
apply.
1) The values in brackets apply to special designs. These sensors are manufactured using special sealing compounds.
Moreover, they feature cases made of stainless steel and cable glands for low-temperature ranges.
WIKA additional information RTD and TC, intrinsically safe designs (Ex i)
Temperature
Ambient
class
temperature
range (T
T1 ... T6
(-50)
Power P
Ambient
i
temperature
range (T
750 mW
(-50)
650 mW
(-50)
550 mW
(-50)
Max. surface temperature
(T
max
)
thermowell tip
a
-40 ... +80 °C
T
(medium temperature) +
1)
M
self-heating
For this, the special
conditions must be
observed (see chapter 4
"Special conditions of use
(X conditions)").
Max. surface temperature
(T
max
)
thermowell tip
a
-40 ... +40 °C
T
(medium temperature) +
1)
M
self-heating
For this, the special
conditions must be
-40 ... +70 °C
1)
observed (see chapter 4
"Special conditions of use
(X conditions)").
-40 ... +80 °C
1)
) at the sensor or
) at the sensor or
5
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tc

Inhaltsverzeichnis