Herunterladen Inhalt Inhalt Diese Seite drucken

Frequency Converter; Accessories; Use - Nederman FlexPAK 800 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für FlexPAK 800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 77
EN
FlexPAK 800/1000
11.
Terminals: X1: 1-80.
12.
Fuse for 24 V DC accessory supply: Fuse F5.
13.
Fuse for Pilot Signal (PS) cable: Fuse F4.
14.
Terminals Protective Earth (PE).
3.8

Frequency converter

WARNING!
The frequency converter is not to be opened until 5 minutes after the supply voltage has
been disconnected. The capacitors inside the converter hold a very dangerous voltage until
they have discharged themselves.
CAUTION!
Do not adjust any parameters in the frequency converter without written authorisation
from the person responsible for this product. See the Declaration of Conformity. Any
unauthorised adjustment may void the warranty.
The unit is not to be started if the cooling hose has been removed.
NOTE! Figure 4 shows the cooling air hose that improves the cooling of the frequency
converter.
NOTE! For parameter settings in the frequency converter, see the 'FlexPAK Frequency
Converter Parameter Table' that is a separate document included with the unit.
The frequency converter controls the unit's motor so that it operates efficiently, as well
as maintaining the unit's vacuum level to help prevent a dangerous underpressure from
developing. The manual for the frequency converter is enclosed.
4

Accessories

The FlexPAK 800/1000 start and control unit is prepared for the connection of Nederman
accessories and customer connections.
The installation of accessories, extra equipment, and functions is described in the manual
for each product and according to the electrical diagrams that came with the unit. Consult
your local Nederman representative for available accessories.
The most common accessory is a PS cable, which allows remote start/stop signalling from
the valves on the duct system. See also Chapter '6 PLC messages' and Chapter '7 PLC
settings' for more information about messages and settings for accessories, and customer
connections.
5

Use

WARNING!
Do not collect material that may cause ignition or blocking. It is strictly prohibited to
collect material that may undergo dangerous chemical or thermal reactions and/or self-
ignite.
WARNING!
Personnel operating FlexPAK 800/1000 are to pay special attention to avoiding discharge
of static electricity. The requirements for the safe use and handling of combustible dust
are described in the explosion protection document. All personnel are to be informed.
20
Risk of electric shock.
Risk of equipment damage.
Explosion risk.
Risk of electric shock.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Flexpak 1000

Inhaltsverzeichnis