Electrical connection

The appliance must be fitted correctly to guarantee elec-
trical safety.
During fitting and maintenance operations, the
appliance must be unplugged from the electrical
supply; fuses must be switched off or removed.
The electrical connections are made before the appliance
is installed in its housing.
Ensure that:
• the electrical installation has sufficient voltage,
• the electrical wires are in good condition,
• the diameter of the wires complies with the installation
requirements.
The microwave oven must be connected with a power
cable (standardized) with 3 1.5mm² conductors (1ph +
1N + ground) that must be connected to a monophase
220-240V~ network via a CEI 60083 standardised recep-
tacle (1ph + 1 neutral + ground lead) or an allpole cut-off
device in accordance with installation rules.
The safety wire (green-yellow) is connected to the
appliance's
terminal and must be connected to the
earth terminal of the electrical set-up.
You must enable the appliance to be disconnected from
the supply network after installation.Disconnection can
be enabled by ensuring that there is an accessible power
plug or by incorporating a switch into the fixed wiring in
compliance with the installation rules.
The fuse in your set-up must be 16 amperes.
If the power cable is damaged , it should be replaced by a
qualified person to avoid danger.
We cannot be held responsible for any accident resulting
from non-existent, defective or incorrect earthing.
If the electrical installation in your residence requires any
changes in order to hook up your appliance, call upon a
professional electrician.
If the microwave malfunctions in any way, unplug the
appliance or remove the fuse corresponding to the
sector where the microwave is hooked up.