Using The Saw - EINHELL TC-TS 2025 U/S Originalbetriebsanleitung

Tischkreissäge
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.2 Assembling the table width extension
(Fig. 6)
Use the screws (a), the spring washers (b),
the nuts (d) and the washers (c) to fasten the
table width extensions (33) loosely to the saw
table (1).
Screw the supports (32) loosely onto the saw
housing and onto the table width extensions
(33) (Fig. 6).
Align the table width extensions (33) level
with the saw table.
Finally, tighten all screws.
6.3 Fitting / removing the saw blade guard
(Fig. 6)
Mount the saw blade guard (2) on the splitter
(5) so that the screw fits through the hole (18)
in the splitter.
Do not tighten the screw (15) too far – the bla-
de guard must be able to move freely.
To remove the saw blade guard, proceed in
reverse order.
Warning!
The guard hood (2) must always be lowered
over the workpiece before you begin to cut.
6.4 Changing the table insert (Figure 8)
To prevent increased likelihood of injury the
table insert should be changed whenever it is
worn or damaged.
Remove the saw blade guard (2).
Remove the 1 countersunk head screws (17).
Take out the worn table insert (6).
To fit the replacement table insert, proceed in
reverse order.
6.5 Setting the splitter (Fig. 9,10)
Danger! Pull out the power plug.
Set the blade (4) to max. cutting depth, move
to 0° position and lock in place.
Remove the saw blade guard (see 6.2).
Take out the table insert (6) (see 6.4).
Slacken the fixing screw (19).
Push up the splitter (5) until the gap between
the saw table (1) and the upper edge of the
splitter (5) equals approx. 10 cm.
The distance between the blade (4) and the
splitter (5) should be 3-5 mm.
Retighten the screw (19) and mount the table
insert (6) (Fig. 8).
Anl_TC_TS_2025_U_S_SPK7.indb 25
Anl_TC_TS_2025_U_S_SPK7.indb 25
GB
6.6 Fitting/replacing the blade (Fig. 7)
Important! Pull out the power plug first.
Remove the table insert by undoing the two
countersunk head screws (see 6.4).
Undo the nut with a size 21 wrench on the
nut itself and a second fork wrench (size 10)
on the motor shaft to apply counter-pressure.
Important! Turn the nut in the direction of
rotation of the saw blade.
Take off the outer flange and pull the old saw
blade off the inner flange by dropping the bla-
de at an angle.
Clean the blade flange thoroughly before fit-
ting the new blade.
Mount and fasten the new saw blade in rever-
se order.
Important! Note the running direction. The
cutting angle of the teeth must point in run-
ning direction, i.e. forwards (see the arrow on
the blade guard).
Refit and set the splitter (5) and the saw gu-
ard (2) (see 6.3., 6.5.)
Check to make sure that all safety devices
are properly mounted and in good working
condition before you begin working with the
saw again.

7. Using the saw

7.1. ON/OFF switch (Fig. 1)
To turn the saw on, press the green button
"I". Wait for the blade to reach its maximum
speed of rotation before commencing with the
cut.
To turn the machine off again, press the red
button "0".
7.2. Cutting depth (Fig. 1)
Turn the hand crank (8) to set the blade (4) to the
required cutting depth.
Turn anti-clockwise:
larger cutting depth
Turn clockwise:
smaller cutting depth
7.3. Parallel stop
7.3.1. Stop height (Fig. 11-14)
The parallel stop (7) supplied with the bench-
type circular saw has two different guide
faces.