LERBAKKEN 10, 8410 RØNDE DENMARK.
For safe installation of 5343A the following must be observed. The module shall only be installed
by qualified personnel who are familiar with the national and international laws, directives and
standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
Certificate
Marking
Standards
Terminal
1, 2
3, 4, 6
Installation note:
For installation in a potentialy explosive gas atmosphere, the following instructions apply:
For nA installation the transmitter must be installed in an metal enclosure e.g. a form B
enclosure, providing a degree of protection of at least IP54 according to IEC60529 that is
suitable for the application and correctly installed or in an enclosure with type of protection Ex
n or Ex e.
For intrinsically safe installation the transmitter must be installed in enclosure providing a
degree of protection of at least IP20 according to IEC60529 and that is suitable for the
application.
Cable entry devices and blanking elements shall fulfill the same requirements
For an ambient temperature ≥ 60ºC, heat resistant cables shall be used with a rating of at
least 20 K above the ambient temperature.
For installation in a potentially explosive dust atmposphere, the following instructions apply:
The surface temperature of the enclosure is equal to the ambient temperature plus 20 K, for a
dust layer with a thickness up to 5 mm.
The transmitter must be mounted in a enclosure according to DIN 43729 that provides a
degree of protection of at least IP6X according to IEC60529, and that is suitable for the
application. Cable entry devices and blanking elements shall fulfill the same requirements.
Revision date:
2013-06-03
14
IECEx Installation drawing
IECEx DEK 13.0036X
Ex nA [ic] IIC T6..T4 Gc
Ex ic IIC T6..T4 Gc
Ex ic IIIC Dc
IEC 60079-0 : 2011, IEC 60079-11 : 2011, IEC 60079-15 : 2010
Ex nA [ic]
Umax = 35 V
Uo: 5 V, Io: 4 mA, Po: 20 mW, Lo: 900 mH, Co: 1000 µF
Version Revision
V1R0
5343V107-DE
WWW.PRELECTRONICS.COM
T4: -40 ≤ Ta ≤ 85ºC
T6: -40 ≤ Ta ≤ 60ºC
Ex ic
Ui : 35 V, Ii:110 mA, Ii:10 µH, Ci:1,0 nF
5343QI02