■ ■ ■ ■ ■ Scale and slider installation notes
Notes
• Do not turn on the power before installing the scale.
• Install the scale with the opening on the scale unit facing downward. If the opening cannot be turned
downward, it should face horizontally. Never install it facing upward. (Fig. 1)
• Remove off the coating around the tap hole to ground the scale unit using the installation surface contact
with the scale.
• Be aware that the scale will be damaged if slider moved outside the measuring length (ML).
• In environments where coolant can splash directly on the scale, be sure to mount a cover on the scale to
protect the scale from splashing. (Fig. 2)
Fig. 1
Opening facing
downward
(
)
• The slider holders are used to secure the slider in place during transport. They are not guides for installation.
• Do not take off the slider holders, if possible, until immediately before securing the slider.
• Even if the slider holders are removed, the plastic hook provided on the slider allows the slider to
maintain an approximate positional relationship with the scale unit.
• The plastic hook can come off if the slider is forcibly twisted or other excessive force is applied. If the
plastic hook comes off, return the plastic hook back to its original position before performing the
installation. (See Fig. 4.)
• After removing the slider holder, be sure to take off the clamp nuts remaining on the scale.
Fig. 3
Clamp nut
Slider holder L
Slider holder R
• Before installing the scale, check that the alignment of the installation surface (or installation brackets) is
within the standards.
• Use a scale installation bracket, where applicable, having a length covering the entire scale length. The
parallelism of the scale may be harmed if only using a bracket divided for the installation section.
• The foot plates on both ends and intermediate foot plate installed on the scale unit are used as the installation
guides.
• Loosely turn the mounting screws first. Determine the alignment and then tighten the screws to fasten the
scale. (See Fig. 5.)
Fig. 5
Bring into contact
Both ends : M8 × 16 (20 N•m)
SR77, CH33
Opening facing
Opening
horizontally
facing upward
(
)
(
)
Clamp nut
Bring into contact
Intermediate foot plate : M4 × 10 (2.7 N•m)
Fig. 2
Fig. 4
Plastic hook
Slider : M4 × 20 (2.7 N•m)
Coolant
(E)