BAM PC-TL-020-K_ _/KA_ _-4
Connection cover for magnetostrictive linear position sensor
3
Construction and function
BAM PC-TL-020-K_ _-4
Radial connection
BAM PC-TL-020-KA_ _-4
Axial connection
Fig. 3-1:
Construction
3.1
Construction
Connection cover: The connection cover
BAM PC-TL-020... includes a suitable connector for
connecting the BTL. Protection rating for the connection
cover is Ex e.
BTL: The BTL7-T...-ZA1K contains the entire processing
electronics. The connection is made through the
connection cover. Construction and function of the BTL
are described in the user's guide for the
(BTL7-T500-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _/ZA1K,
BTL7-T500-M_ _ _ _-J-DEX_-K_ _/ZA1K).
Electrical connection: The electrical connection in the
terminal chamber is made using a suitable connector. This
is plugged in and threaded on by the user. On the
customer side a cable is brought out (see section 4.4 on
page 9).
Attachment: The connection housing is attached using
three M5 screws. Screws and washer are included in the
scope of delivery.
www.balluff.com
Ø 10.6
45
BTL7-T...-ZA1K
~20
47
BTL7-T...-ZA1K
3.2
Use of the connection cover BAM PC-TL-020 makes it
possible for the user to disconnect the cable from the BTL
for installation and/or service.
The connection cover is offered in two versions:
–
Radial cable out
–
Axial cable out
The "increased safety" classification requires that ignition in
the terminal chamber is not possible. This is achieved as
follows:
–
Use of a certified connector which is double secured:
plugged in and threaded on.
–
Good mechanical security of the cable leads.
–
Maintaining of the conductor distances.
BAM PC-TL-020... is intended only for use with
the BTL7-T...-ZA1K!
Function
Use of the connection cover does not affect the
operation or function of the BTL.
english
Ø 63
Ø 60
Ø 63
7