Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Schedule - Kärcher SB MU 908 Originalbetriebsanleitung

Hd-pumpenmodul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Time
Activity
once a year
Clean the filter
before the
frosting peri-
od starts
opinion
opinion
opinion
opinion
opinion
opinion
daily
opinion
opinion
opinion
opinion
opinion
opinion
opinion
empty
Initially dai-
empty
ly, later on
based on ex-
perience
Everyday
opinion
under frost
conditions
After 40 op-
opinion
erating hours
or once a
week
opinion
opinion
opinion
opinion
opinion
opinion
opinion

Maintenance schedule

Assembly affectedPerformance
Antifreezing circula-
Empty and clean the collection chute for the frost protection water.
tion
Clean the filter on the immersion pump.
Clean filter of the anti-freeze pump (on the frame of the high-pressure
pumps).
Clean the tool compartment and check for free flow.
Clean the sieve in front of the orifice plate (in the area of the high pres-
sure pump outlet) (see "Maintenance work").
Fill the collection chute for the frost protection water with fresh water.
Warm water gener-
Check function.
ation
Antifreezing circula-
Check the submersible pump in the collection chute for proper function.
tion
Check if at least 0.5 l/h of water exit each hand spray gun.
Adjust the overflow passage on the submersible pump if necessary.
External thermostat Measure the outside temperature in the vicinity of the outside temper-
ature sensor and compare it with the outside temperature on the dis-
play of the control.
Have the setting corrected by the aftersales service if deviations ex-
ceed 1...2 °C.
Frost protection
Switch on the frost protection pump (see Chapter "Manual proce-
with lost water
dures").
Check if at least 0.5 l/h of water exit each hand spray gun.
Heated foam hoses Check for cracks or other damages.
Emergency frost
Turn the main switch to position "0".
protection
Check if at least 0.8 l/h of water exit each hand spray gun.
High pressure hos-
Check high pressure hoses for mechanical damages such as scraping,
es, foam hoses
visible hose duck, bends, porous and cracked rubber. Replace dam-
(with 2 tool model)
aged high pressure hoses.
Information signs at
Check whether the warning boards for the users are available and leg-
the washdown yard
ible.
Washing station
Check the function of the washing station lighting and replace defective
lighting
lights.
Spray lance
Check for tightness; replace O-ring if necessary. Nozzle protection and
handle pipe OK? Replace if necessary.
Hand spray gun
Check for tightness; replace O-ring if necessary.
Can the high-pressure hose be rotated, and is the lever running
smoothly? Lubricate if nessary (see section „Maintenance work").
Tool storage box
Check from the outside for foreing matters and contamination. Remove
coarse contaminants.
Fill levels of the de-
Check filling level, refill or replace if necessary.
tergent container
Coins container
Open the coin acceptor doors and empty the coin container.
Compressor
Drain the condensate from the pressure container of the compressor. Operator
Antifreezing circula-
Check the submersible pump in the collection chute for proper function.
tion
Check if at least 0.5 l/h of water exit each hand spray gun.
Adjust the overflow passage on the submersible pump if necessary.
Tightness of systemCheck pumps and pipes for leaks. Inform Customer Service if there is
oil under the high pressure pump, if more than 3 drops of water drop
out of the high pressure pump when the pump is running.
Oil condition
Milky oil indicates that it contains water. Inform Customer Service.
Check oil level in
The oil level must lie between the MIN and MAX markings; else refill. Operator
the high pressure
pumps
Detergent hoses
Visual inspection of the high-pressure jet whether it contains detergent.
with filter
Clean the filter if necessary.
Entire plant
Check the functions of all wash programs.
Salt stock in the salt
Is the salt level above the water level? If required, top up softening
tank
salts.
Residual hardness
Draw water at the soft water test cock and check residual hardness.
of softened water
Nominal value: below 10 °dH
Filter for frost-pro-
Check filter for soiling and reinsert
tection pump
22
-
EN
By whom
Operator/
Customer
Service
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
59

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sb mu 608

Inhaltsverzeichnis