6.6 Machine maintenance

6.6.1 Cleaning
Clean the machine on a daily basis.
After cleaning
– all cables, hoses, connections and connectors
are to be checked for leakage, holed con-
Attention
nections, chafing points and other damage.
– Detected faults are to be eliminated imme-
diately.
No combustible or aggressive materials are to be
used for cleaning.

6.6.2 Tightening torques

8.8
ø
Nm
ft lb
M 4
3
2
M 5
6
4
M 6
10
7
M 8
25
18
M 10
49
36
M 12
85
62
M 14
135
99
M 16
210
154
M 18
300
221
M 20
425
313
M 22
580
427
M 24
730
538
TAB01001.cdr
Strength classes for screws with untreated, non-lubricated sur-
face.
The values result in 90% utilisation of the apparent yielding point
at a friction coefficient µ = 0.14.
Tightening torques are checked for correctness using torque
wrenches.
When using lubricant MoS2, the specified values do not apply.
Renew self-locking nuts after each removal.
Important

6.6.3 Screwed connections

With vibrating machines, it is important to check the screwed
connections for tightness at regular intervals. Observe tighten-
ing torques.
6.6.4 Changing rubber buffers
Inspect the rubber buffers for cracks and chipping as well as
tightness and immediately replace if damaged.
10.9
12.9
Nm
ft lb
Nm
ft lb
4,4
3
5
8,7
6
10
15
11
18
13
36
26
43
72
53
84
125
92
145
106
200
147
235
173
310
228
365
269
430
317
500
368
610
449
710
523
830
612
970
715
1050
774
1220
899
6.6.5 Exciter: Oil change / Oil level
Change oil when it is warm.
The venting screw (3) must always first be unscrewed
when checking the oil level or changing the oil.
Important
4
B8299100.cdr
7
• Unscrew venting screw (3), oil filling plug/dipstick (1) and oil
drain plug (2).
31
Care is to be taken with the draining of hot oil :
61
danger of scalding!
Danger
• Drain-off old oil.
Collect oil which has run out or overflowed and
dispose it in an environment friendly manner.
Environment
• Screw-in oil drain screw (2).
• Fill-in new oil through the oil fill hole (1). See lubrication plan
for quantity and quality.
GETRIEBEÖL
GEAR OIL
gem. JDM J20C
1
MAX
MIN
When the dipstick is screwed in, the optimal oil
level is between the «MIN» and «MAX» markings.
Attention
• Replace oil filling plug/dipstick (1) and venting screw (3).
• Unscrew oil filling plug/dipstick (1), check the oil level again
and top up with oil if necessary.
• Replace oil filling plug/dipstick (1).