Braking during opening is enabled or disabled:
On: Activated braking in the closing phase
SLDO
Off: Activated braking in both opening and closing phases
Braking starts next to the opening and closing mechanical stops
Slow closing of the door for the entire stroke is enabled or disabled.
Compliance with regulations in force is facilitated in case of heavy doors.
CLSL
On: slow closure of the door
Off: normal closure of the door
MENU
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-
by-step function.
PP
Press the transmitter key to be assigned to this function.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.
By selecting this function, the receiver waits (Push) for a transmitter code to be assigned to the SAIR
function.Press the transmitter key to be assigned to this function.
Sair
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from
memory.
CLR
If the code is valid, it will be erased and OK will be displayed.
If the code is not valid or it is not in memory, the Err message will be displayed.
RTR
The receiver memory is completely erased. Confirmation is asked.
MENU
The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is
NMAN
pressed once more, the last 4 digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.
The self-calibration of the triggering thresholds of the anti-crash device (amperometric sensor), as well
auto
as the stroke learning are performed. See paragraph SELF-LEARNING
RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash, if the push-
RES
button<PG> is pressed once more, the control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from
the receiver.
After any LOGIC change or control panel reset, it is necessary to perform a self-learning procedure
RUN SELF-LEARNING AND ANTI-CRUSHING DEVICE SETTING
When operator assembly and wiring is completed, parameters and logic are programmed, self learning allows the operator
to learn the stroke and self adjusts amperometric sensor thresholds.
First of all place the opening and closing mechanical stops:
- manually release the door and completely close it. Place the closing mechanical stop in the closed position on the
driving carrier and fix it.
- completely open the door. Place the opening mechanical stop in the open position on the driving carrier and fix it.
For further information, please refer to the operator (JM4) manual.
Now the opening and closing positions can be memorized:
Enter menu Auto and press the button < PGM > , PUSH will be displayed.
Press again the button < PGM >: self-learning is beginning: PRG will be displayed, and the control panel completes at
least three opening/closing cycles.
When the procedure is completed OK will be displayed.
This procedure can be followed from any position of the gate/door leaf and can be stopped at any moment by pressing
keys <+> and <-> at the same time, or through the activation of STOP/PHOTO/DAS/PP/CLOSE inputs.
If the procedure doesn't have positive result, the message ERR is displayed, please verify possible obstacles or attrition
points.