Herunterladen Inhalt Inhalt Diese Seite drucken

Instructions For Repositioning Silencer Housings From K07 To K12 - Ms Gor; Electric Motor - FPZ SCL K04 MS-GOR Betriebsanleitung

Seitenkanalverdichter/-vakuumpumpen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 104
Check the axial alignment of the semi-joints in at
least four places using a knife-edge rule or similar.
Check the angular alignment by measuring the
distance of the semi-joints in at least four places.
Do not turn the transmission in taking the
measurements.
Make sure the correction of one alignment does
not change the other.
Protect the couplings with the coupling covers,
fixing them to the connection flange using suitable
screws.
NOTE FOR THE
Regarding this, also consult the instruction manual for elastomer joints.
USER

12.4 INSTRUCTIONS FOR REPOSITIONING SILENCER HOUSINGS FROM K07 to K12 - MS GOR

The 'SCL K - GOR' series has been designed for maximum flexibility
in positioning the silencer housings in order to allow different
installation configurations.
The blower is normally supplied with silencers fitted on the
blower body.
If this arrangement has to be changed, establish the required
arrangement of the silencer housings. See the INSTALLATION
DIAGRAMS in the first section.
Remove and refit the housings and blind flanges according to
the diagram to obtain the desired configuration.
Removing the blind flange (A)
Place the unit horizontal, resting the base on a flat and stable
surface.
Undo the screws, remove the blind flanges, the gasket and the
silencer housings.
Positioning of silencer housings and blind flanges (B)
Invert the positions of the silencer housings, blind flanges and
gaskets.
Fitting of blind flanges and silencer housings (C)
Fit the blind flanges on the housing with screws, not forgetting
the gaskets.
Fit the silencer housings on the cover using screws, not
forgetting the gaskets.
Danger due to rotating parts: impeller.
The danger of shearing due to the rotating impeller can exist even when the machine off, if it is started manually.
Therefore use suitable work clothes and personal protection equipment.

12.5 ELECTRIC MOTOR

Make sure to comply with all the safety measures and instructions given in the electric motor
instruction manual.
Make sure the mains power supply voltage and frequency match the values specified on the motor
rating plate.
FPZ-MI-K MS-GOR/GVR-EU-R00-15
A
B
C
44 / 122

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis