14.3 REPLACING THE SOUND ABSORBING MATERIAL

When replacing the sound absorbing material in the silencers, proceed as follows:
Undo the screws (1)
Disconnect the silencer housings (2)
Remove the sound absorbing material from the silencer housings (3)
Recover the support mesh (4)
Replace the sound absorbing material and assemble by proceeding in
reverse order.

14.4 INTERNAL CLEANING

To clean the inside, proceed as follows:
Place the unit upright, resting the fan cover on a flat and stable surface (1)
Undo the screws (2)
Undo the cover screws (2)
Remove the cover (3)
Undo the screw and remove the washer (4)
Remove the bearing and bearing cover (4)
Remove the impeller (5)
Clean and assemble by proceeding in reverse order
Use a threaded bar to correctly position the bearing cover (6).
Seal with System RS01 Arexons or Loctite 5970
1
4

14.5 LIFE OF BEARINGS

In normal operating conditions (values given in the SPECIFICATIONS) the machine's bearings should be replaced by FPZ personnel
after 25000 hours or 3 years, whichever comes first.