Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Characteristics; Safety Devices - EdilKamin NILO Installations-, Betriebs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 110
Models and dimensions
13
Hot air channel
Ø 100 mm
Serial socket
Rs232 fitting
68

ELECTRICAL CHARACTERISTICS

Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on mains power
supply* (see page 34)
Protection on electronic circuit board
FEATURES
13
Combustion
air Ø 40 mm
Smoke outlet
7
Ø 80 mm
230Vac +/- 10% 50 Hz
Yes
100
W
400
W
Infrared
2A, 250 Vac, 5x20 Fuse
2A, 250 Vac, 5x20 Fuse
THERMOTECHNICAL CHARACTERISTICS
Nominal power
Efficiency nominal power
Emissions CO (13% O2) nominal power
Smoke mass nominal power
Reduced power
Efficiency reduced power
Emissions CO (13% O2) reduced power
Smoke mass reduced power
Maximum overheated smoke
Minimum draught
Autonomy (min/max)
Fuel consumption (min/max)
Hopper capacity
*
Heatable volume
Weight NILO including packaging
Weight DANUBIO including packaging
Weight RIO including packaging
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
*
The heatable room dimensions are calculated on the basis of
pellets with an lhv of at least 4300 kcal/kg and home insulation
in compliance with Italian law 10/91, and subsequent changes
together with an expected heat output of 33 Kcal/m³ per hour.
* It is also important to consider the position of the stove in the
room to be heated.
The data shown above is purely indicative.
EDILKAMIN s.p.a. reserves the right to make changes
to these products to improve their performance with
no prior warning.

SAFETY DEVICES

THERMOCOUPLE: placed at the smoke outlet to
detect the temperature. Turns the stove on and off and
controls its operation based on defined parameters.
AIR FLOW SENSOR:
placed in the air inlet channel.
This intervenes if an anomaly is detected in the combustion air
flow and causes insufficient circulation in the smoke ducts.
SAFETY THERMOSTAT: trips when the temperature
inside the stove is too high. It stops pellet loading, causing
the stove to go out.
33
13,2
kW
92,5
%
194
ppm
13,5
g/s
5,11
kW
93,3
%
375
ppm
7,4
g/s
96,4
°C
12
Pa
8,1/21,5
hours
1,1/2,9
kg/h
23,5
kg
345
m
3
262
kg
240
kg
277
kg
80
mm
40
mm