Malfunction/error
Porous weld seam
Wire burns back into current
contact tip at start of process
Error table ERROR CODES:
Error CODE
E02
E08
E11 bis E14
E24 bis E24
E29
E30
E80
E81
E88
E91 / E92
E94 / E95
E96 / E97
E99 - CAN
Operating manual
Cause
Work piece surface polluted(paint,
rust, oil, grease)
No shielding gas(solenoid valve not
opening)
Insufficient shielding gas
Gas nozzle polluted
Deficient wire feed, feed rollers
idling
Cause
Main voltage to high (>480V) or
main under voltage (<350V);
Phase failure
Incorrect machine configuration
(e.g. inoMIG 500 instead inoMIG
350)
Temperature sensors 1-4
interruption or short circuit
No communication with the power
supply unit
Error EEPROM
Wrong machine configuration
inoMIG / tecMIG / conMIG
Wrong Software version in
machine or control box MC
Encoder Motor defective, cable
interruption, wrong motor type set
Wrong configuration in control box,
e.g. 2 wire feeder mode
Faulty data transfer on CAN wiring
Faulty CAN protocol
Communication between wire
feeder (MC control box) and
machine completely interrupted
inoMIG 350/400
Remedy
Clean surface
Check / exchange solenoid valve
or gas tube
Check shielding gas at pressure
reducer
Check gas line for leakage
Clean gas nozzle
See chapter 28
Remedy
Check main voltage
Control box must be reconfigured
Check wiring of the temperature
sensors, check sensor
Check the power supply line
Back to manufacturers
Change machine type in the control
box MC
Software update
Check cable and encoder,
check motor type in control box
Check configuration in control box
MC
Check wiring
Check configuration in control box
MC
Intermediate hose pack broken,
connector defective, control box
MC or control board in the machine
defective