6 - 7 - 8
230V AC MOTOR
9 - 12
OPEN/CLOSE
10 - 12
PEDESTRIAN
11 - 12
STOP
13 - 14
SENSITIVE EDGE
13 - 15
PHOTOCELLS
16 - 17
AERIAL
18 - 19
2
RADIO CH
nd
GATE OPEN
20 - 21
WARNING LIGHT
22 - 24
PHOTOCELL TX
23 - 24
PHOTOCELL RX
OPEN LIMIT
25 - 26
SWITCH (FCA)
CLOSE LIMIT
25 - 27
SWITCH (FCC)
LOGIC ADJUSTMENTS
TRIMMER
T.C.A.
Automatic closing time adjustment from 5 to 120 seconds.
RALL.
Deceleration time adjustment: from 0 to 15 sec. before the limit switch;
Note: the automation must perform a complete opening and closing manoeu-
vre before setting the deceleration.
FR.
Motor torque adjustment. The trimmer is set to provide sufficient thrust to work the
gate without exceeding the limits established by current standards. Turn the TRIM-
MER clockwise (+) to decrease the motor torque adjustments; turn it anticlock-
wise (-) to increase.
J 1
When the jumper is open, maximum starting thrust does not exceed 400Nm, in com-
pliance with EN 12453. When the jumper is closed, maximum starting thrust equals
the true capacity of the gear motor (used for non-EEC markets).
14
MOTOR output single-phase 230 Vac common= 6; closing= 7;
opening= 8; connect the capacitor between terminals 7 and 8.
OPEN/CLOSE pushbutton input (Normally Open contact);
PEDESTRIAN pushbutton input (Normally Open contact);
STOP pushbutton input (Normally Closed contact);
FIXED SAFETY EDGE input (Normally Closed contact);
Works only when the gate is opening; temporarily stops the
gate and partially closes it by about 20 cm in order to allow the
obstacle to be removed. (13=Common).
PHOTOCELL OR SAFETY DEVICES input (Normally Closed
contact); They stop the gate during closing and totally reopen it;
they temporarily stop the gate during opening in order to allow
the obstacle to be removed (if dip switch n° 3 set to ON), (13=
Common).
Note:
the photocell transmitter must always be supplied
by terminals no. 22 and no. 24, since the safety system test
(phototest) is carried out on it. Without this connection, the
control unit does not work. To override the testing of the
safety system, or when the photocells are not used, set
dip-switch no. 7 to OFF.
433,92 MHz built-in RX aerial input; 16= EARTH 17= SIGNAL
2
RADIO CHANNEL output used for opening/closing another
nd
gate or controlling garden illumination.
Warning: to connect other devices to the 2nd Radio Chan-
nel (area lighting, pumps, etc.), use an additional auxiliary
relay.
GATE OPEN LED output 24 Vac - max. 3 W; the LED flashes
slowly during opening, remains on when the gate is open and
flashes rapidly during closing.
24 Vac 10 W POWER output for PHOTOCELL TX max. no. 1
photocell transmitter.
24 Vac 10 W POWER output for PHOTOCELL RX, EXTERNAL
RECEIVERS, etc. connect a max. of 3 pair of photocells;
OPEN LIMIT SWITCH input (Normally Closed contact);
25= Common.
CLOSE LIMIT SWITCH input (Normally Closed contact);
25= Common.